
Packing Size:
1 pc/box 、 20 pcs/box
30 pcs/box 、50 pcs/box

Specimen Type:
blood / serum / plasma

Shelf Life:
24 months

Storage:
2-30C°

Packing size:
1 pc/box 、 20 pcs/box 、30 pcs/box
50 pcs/box

Storage:
2-30C°

Specimen type:
blood / serum / plasma

Shelf Life:
24 months
Watch us
Watch us
MEDOMICS
MEDOMICS

VNT

Sample
Time of testing
Laboratory level
Operation
blood / serum / plasma
5 days
BSL-3
High requirement
Rapid Test

Sample
Time of testing
Laboratory level
Operation
blood / serum / plasma
15min
BSL-2
basic
VNT

Sample
Time of testing
Laboratory level
Operation
blood / serum / plasma
5 days
BSL-3
High requirement
Rapid Test

Sample
Time of testing
Laboratory level
Operation
blood / serum / plasma
15min
BSL-2
basic
COVID-19 Case Timeline
COVID-19 Case Timeline

Method by Medomics
method by Medomics

Clinical Evaluation Report And Certification
Clinical Evaluation Report And Certification


FOR IN VITRO DIAGNOSTIC USE ONLY.
FOR SELF-TESTING.
PLEASE READ INSTRUCTIONS CAREFULLY
BEFORE YOU PERFORM THE TEST.
FOR IN VITRO DIAGNOSTIC USE ONLY.
FOR IN VITRO DIAGNOSTIC USE ONLY.

Sample Requirements
Sample Requirements
01

02

03

04

05

from your finger
06

07

08

of diluent into sample well.
09

Test Procedure
Test Procedure
Do not open pouch until ready to use.
Wash your hands thoroughly with soap and water, dry your hands before performing the test. Massage the selected fingertip to be tested, then clean the fingertip with alcohol pad provided in the kit.Remove the protective cap from the lancet, then place end of lancet on the test site and push the lancet down. Wipe off the first drop of blood from your finger using the same alcohol pad. Hold the capillary tube and dip it into the fingertip blood sample, keep the capillary tube horizontal, do not cover the air hole. The capillary tube would absorb blood sample until the sample filled the whole tube to the scale line. Cover the air hole with fingers, squeeze the gasbag to inject the blood into the sample well on test cassette. Twist to open the buffer capsule and squeeze all buffer into sample well. Read the result after 15 minutes and the result that have run over 20 minutes are invalid.
DISPLAY OF THE RESULT / EXPECTED VALUE
DISPLAY OF THE RESULT / EXPECTED VALUE
“C”:Quality Control Line “T”:Detection Line “S”:Sample Well
“C”:Quality Control Line

• Positive result: If both thequality control C line and the detection T line appear, it means that the SARS-CoV-2 neutralizing antibody has been detected, and the result is positive for neutraliz-ing antibody.
“T”:Detection Line

• Negative result: If only the quality control C line appears and the detec-tion T line does not show color, it means that the SARS-CoV-2 neutraliz-ing antibody has not been detected and the result is negative.
“S”:Sample Well

• Invalid result: If the quality control Cline cannot be observed, the result is invalid regardless of whether there is a detection line display, and the test should be repeated.

• Positive result: If both thequality control C line and the detection T line appear, it means that the SARS-CoV-2 neutralizing antibody has been detected, and the result is positive for neutraliz-ing antibody.
• Negative result: If only the quality control C line appears and the detec-tion T line does not show color, it means that the SARS-CoV-2 neutraliz-ing antibody has not been detected and the result is negative.
• Invalid result: If the quality control Cline cannot be observed, the result is invalid regardless of whether there is a detection line display, and the test should be repeated.
Related Products
Read more +
Related Products
Read more +
Search for more you need
Enter keywords, you can query more product information you would like to know.
Contact Information
E-mail:
Address:Building 01, Phase 6, No.71, Xinghui Road, Jiangbei New Area, Nanjing
About Us
Product Center
Jiangsu Medomics Medical Technology Co,Ltd Powered By www.300.cn 苏ICP备18065762号